5069 if8 manual - I saw this thread and thought "there's no way in the world a 5069-IF8 doesn't support 3 wire transmitters" and figured I'd find a working example onsite to prove it, then post back. I then promptly forgot about it. But I remembered this morning, and yes, I have wired 2, 3 and 4 wire 4-20mA transmitters to a 5069-IF8 and it works just fine.

 
View and Download Allen-Bradley 5069-IF8 user manual online. Analog I/O Modules 5000 Series in Logix5000 Control Systems. 5069-IF8 i/o systems pdf manual download. Appendix A Troubleshoot Your Module Table 29 describes the I/O Status indicator on 5069 Compact I/O analog output modules. . Alvy

If you're trying to use a common 3-wire analog device like a transmitter with +24V, analog out, and common, then I can 100% verify that they are compatabile with the IF8. Just requires a 24V power supply and tying the DC com to the (-) of the IF8 input channel. Yes, it’s a standard 3 wire analog. Can you confirm that on the 5069-if8 (not the ...5069-IF8: Manufacturer: Allen-Bradley / Rockwell Automation: Description: Allen-Bradley 5069-IF8 5069 Compact I/O 8-Ch Current/Voltage Input Module: Full Description: Allen Bradley 5069-IF8 5069 CompactLogix Compact I/O 8 Channel Current/Voltage Analog Input Module: UPC / GTIN: 00885630530062: Status: Current Product5069-AENTR, 5069-AENTRK(1) (1) A catalog number followed by a “K” indicates a conformal coating option. 10 Mbps 100 Mbps 1 Gbps Yes Yes Yes No Explicit Implicit Yes 5069-AEN2TR 10 Mbps 100 Mbps 1 Gbps Yes Yes Yes No Not Supported Yes IMPORTANT Protected Mode is only available with the 5069-AENTR adapter. The 5069-AEN2TR adapter does not ... View and Download Allen-Bradley 5069-IF8 user manual online. Analog I/O Modules 5000 Series in Logix5000 Control Systems. 5069-IF8 i/o systems pdf manual download. Appendix A Troubleshoot Your Module Table 29 describes the I/O Status indicator on 5069 Compact I/O analog output modules.Series information for 5069-IF8. For additional information about 5069-IF8 check the data sheet or manual. Also check the manual PDF for all wiring diagrams, compatibility, troubleshooting, specifications, installation instructions, and accessories (such as batteries, terminal blocks, or cables) regarding 5069-IF8.Analog I/O Module Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8 High-speed Counter Module Catalog Number 5069-HSC2xOB4 Serial Module Catalog Number 5069-SERIAL Field Potential Distributor Catalog Number 5069-FPD Address Reserve Module Catalog Number 5069-ARM EtherNet/IP Adapter Catalog Number 5069-AENTR, 5069-AEN2TRUser Manual. Original Instructions. 5000 Series Analog I/O Modules in Logix5000 Control Systems. Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8.5094-IF8, 5094-IF8XT Installation Download. 5094-IF8IH, 5094-IF8IHXT Installation ... FLEX 5000 Analog Isolated Current/Voltage/HART Input and Output Modules User ManualAustralian RCM. IECEx Scheme. ATEX. This product was certified with the above certifications as of 2023-09-04. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.I/O Systems Allen-Bradley 5069-IF8 User Manual. Analog i/o modules 5000 series in logix5000 control systems (166 pages) I/O Systems Allen-Bradley 1756-IF8I User Manual. High resolution analog i/o modules (226 pages) I/O Systems Allen-Bradley 1734-IE2C Installation Instructions Manual.View and Download Allen-Bradley 5069-IF8 user manual online. Analog I/O Modules 5000 Series in Logix5000 Control Systems. 5069-IF8 i/o systems pdf manual download. Appendix A Troubleshoot Your Module Table 27 - Module (MOD) Status Indicator - 5069 Compact I/O Analog I/O Modules...DDS Analog I/O Module Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8 High-speed Counter Module Catalog Number 5069-HSC2xOB4 Serial Module Catalog Number 5069-SERIAL Field Potential Distributor Catalog Number 5069-FPD Address Reserve Module Catalog Number 5069-ARM EtherNet/IP Adapter Catalog Number 5069-AENTR, 5069-AEN2TRMay 7, 2022 · The 5069 analog I/O modules for use with this controller are 5069-IF8 (differential current/voltage) and 5069-IY4. The IY4 is able to take thermocouple and RTD inputs along with diff current and voltage. The user manual ( Compact 5000 I/O Analog Modules User Manual) for both of these modules state that 3-wire analog devices " are not supported ... 2 Rockwell Automation Publication 5069-TD001D-EN-P - October 2016 5069 Compact I/O Modules Specifications Summary of Changes Changes to the publication are listed in this table. Digital I/O Modules Topic Page Addition of information for the 5069-IA16 digital input module 3 Addition of information for the 5069-OA16 digital output module 18 It seems like the 5069 analog cards are much more sensitive to bad power. We had the exact same issue with brand new IF8 modules. We had 4 of them with the same issue across machines. The thing we noticed across the good/bad modules was that the bad ones were much older manufacturing date and an earlier revision.We have 1 Allen-Bradley 5069-IF8 manual available for free PDF download: User Manual Allen-Bradley 5069-IF8 User Manual (166 pages) Analog I/O Modules 5000 Series in Logix5000 Control Systems5069-RTB18-SCREW, 5069-RTB14CJC-SCREW: 0.4 Nm (3.5 lbin) Overvoltage protection, max ... The Allen-Bradley 5069 Compact 5000 series 5069-IF8 module is an analog input module. It is an 8-channel current/voltage input module. It offers differential, non-isolated inputs that are able to connect with different input devices. The module comes with 16-bit resolution and it has an update time of 1 millisecond.Rockwell new Compact Logix I/O. Hello, Rockwell is out with new compactlogix series 5069 series I/O. I have the 2017 AutoCAD electrical, but this series does not exist in the PLC database. I can use the PLC database editor to start entering the cards that I need but, I am wondering if anything has already been created for autocad electrical.The 5069-FPD field potential distributor breaks field-side power distribution in a CompactLogix™ 5380, CompactLogix 5480, or Compact GuardLogix® 5380 control system or a Compact 5000™ I/O system and creates a new SA power bus to the right of the field potential distributor from which Compact 5000 I/O modules can draw current. 5069-L310ERS2K, 5069-L310ERMS2K, 5069-L320ERS2K, 5069-L320ERMS2K, 5069-L330ERS2K, 5069-L330ERMS2K, 5069-L350ERS2K, 5069-L350ERMS2K Compact GuardLogix 5380 SIL 3 Controller Catalog Numbers 5069-L306ERMS3, 5069-L310ERMS3, 5069-L320ERMS3, 5069-L330ERMS3, 5069-L340ERMS3, 5069-L350ERMS3, 5069-L380ERMS3, 5069-L3100ERMS3 Compact GuardLogix 5380 SIL 3Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8 User Manual. Important User InformationAustralian RCM. IECEx Scheme. ATEX. This product was certified with the above certifications as of 2023-09-04. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries. 2 Rockwell Automation Publication 5069-TD001D-EN-P - October 2016 5069 Compact I/O Modules Specifications Summary of Changes Changes to the publication are listed in this table. Digital I/O Modules Topic Page Addition of information for the 5069-IA16 digital input module 3 Addition of information for the 5069-OA16 digital output module 182 Rockwell Automation Publication 1756-UM533F-EN-P - August 2023 ControlLogix HART Analog I/O Modules User Manual Important User Information Read this document and the documents listed in the additional resources sect ion about installation, configuration, and operatio n of this equipment before View and Download Allen-Bradley 5069-IF8 user manual online. Analog I/O Modules 5000 Series in Logix5000 Control Systems. 5069-IF8 i/o systems pdf manual download. Appendix A Troubleshoot Your Module Table 27 - Module (MOD) Status Indicator - 5069 Compact I/O Analog I/O Modules...Note: The selected IO Product needs the Terminal kits 5069-RTB18-SCREW or 5069-RTB18-SPRING. Terminal kits are pre-packed in a pack of 5pcs I/O Modules Category: Analog Type: Input No of Inputs/Outputs: 8 Catalog Number Catalog Number: 5069 Compact I/O 8 Channel Voltage/Current Analog Input Module Note• The 5069-IA16 module inputs use a shared common. The inputs have a return through internal module circuitry to the SA (–) terminal on the SA Power RTB. • If you install modules in a 5069 Compact I/O system that use AC SA power and DC SA power, you must install them on separate SA Power buses. 5069 Compact I/O 16 Channel 24VDC Sink Input Module. Lifecycle status: ACTIVE. Find a Distributor. Learn how to avoid the risks of unauthorized and counterfeit products. Find Product Drawings. Add to BoM. Get Support. 5069-IB16. Find a Distributor. I saw this thread and thought "there's no way in the world a 5069-IF8 doesn't support 3 wire transmitters" and figured I'd find a working example onsite to prove it, then post back. I then promptly forgot about it. But I remembered this morning, and yes, I have wired 2, 3 and 4 wire 4-20mA transmitters to a 5069-IF8 and it works just fine. Use your product. Compact I/O ASCII Module User Manual Compact I/O BOOLEAN Module User Manual Compact I/O BOOLEAN Module Reference Manual Compact High-speed Counter Module User Manual 1769-IR6 RTD/Resistance Input Module User Manual 1769-IT6 Thermocouple/mV Input Module User Manual.Our Bulletin 5069 Compact 5000™ I/O modules provide high-performance control in a compact design, and expand the performance capabilities of the Logix platform. They are the local I/O modules in a CompactLogix™ 5380, Compact GuardLogix® 5380, or CompactLogix 5480 system and safety options are available. These modules are the ideal ... User ManualOriginal Instructions Compact 5000 I/O Analog Modules Catalog Numbers 5069-IF8, 5069-IY4, 5069-IY4K, 5069-OF4, 5069-OF4K, 5069-OF8 2Rockwell Automation Publication 5069-UM005C-EN-P - January 2022 Compact 5000 I/O Analog Modules User Manual Important User InformationIssue 3: Updated ratings on 5069-IB6F3W and 5069-OF8 to 900mA and 250mA respectively, added models 5069-IA16, 5069-OB8, 5069- OA16 and 5069-OW16 and updated drawings. Issue 4: Update was to clarify the spacings verdict in Clause 13 from the IEC 60079-15 standard. The 5069-OB16, 5069-OB16F, and 5069-OB16K digital 16-point sourcing output modules drive output devices. The data that is sent to the modules from a controller and some input modules determines the 5069-OB16, 5069-OB16F, and 5069-OB16K module behavior. You can use time-scheduled output control on the 5069-OB16F output modules. Analog I/O Module Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8 High-speed Counter Module Catalog Number 5069-HSC2xOB4 Serial Module Catalog Number 5069-SERIAL Field Potential Distributor Catalog Number 5069-FPD Address Reserve Module Catalog Number 5069-ARM EtherNet/IP Adapter Catalog Number 5069-AENTR, 5069-AEN2TR5069 Compact I/O 16 Channel 24VDC Sink Input Module. Lifecycle status: ACTIVE. Find a Distributor. Learn how to avoid the risks of unauthorized and counterfeit products. Find Product Drawings. Add to BoM. Get Support. 5069-IB16. Find a Distributor. 5069-RTB18-SCREW, 5069-RTB14CJC-SCREW: 0.4 Nm (3.5 lbin) Overvoltage protection, max ...Describes how to install and wire the 5069-IF8 analog input module. 5069 Compact I/O Analog 4-channel Current/Voltage/RTD/Thermocouple Input Module Installation Instructions, publication 5069-IN011 Describes how to install and wire the 5069-IY4 analog input module. 5069 Compact I/O Analog Current/Voltage Output Modules Installation Instructions,5069-RTB18-SCREW, 5069-RTB14CJC-SCREW: 0.4 Nm (3.5 lbin) Overvoltage protection, max ... The 5069-OB16, 5069-OB16F, and 5069-OB16K digital 16-point sourcing output modules drive output devices. The data that is sent to the modules from a controller and some input modules determines the 5069-OB16, 5069-OB16F, and 5069-OB16K module behavior. You can use time-scheduled output control on the 5069-OB16F output modules.User Manuals, Guides and Specifications for your Allen-Bradley 5069-IF8 I/O Systems. Database contains 1 Allen-Bradley 5069-IF8 Manuals (available for free online viewing or downloading in PDF): Operation & user’s manual .I saw this thread and thought "there's no way in the world a 5069-IF8 doesn't support 3 wire transmitters" and figured I'd find a working example onsite to prove it, then post back. I then promptly forgot about it. But I remembered this morning, and yes, I have wired 2, 3 and 4 wire 4-20mA transmitters to a 5069-IF8 and it works just fine.5069-IF8 Installation Download. 5069-IY4, 5069-IY4K Installation ... Compact 5000 I/O High-Speed Counter Module User Manual Looking for more? Download. CompactLogix ... Sep 26, 2022 · 5069-IF8 FieldPowerOff = 1. Got a trouble call with a 5069-IF8 module that has all the channels flashing red. Upon logging in, I see that each channel is faulted with the FieldPowerOff bit set to 1. I had them verify the SA power is good, which it is, and another 5069-IF8 module 2 slots down is functioning fine, so SA power appears to be good. 1746-to-5069 I/O Conversion System Installation ... 1746-NO4V 4-Channel Analog I/O Modules User Manual Download. 1746-NI8 Analog Input Module User Manual 5069-RTB18-SPRING. Allen-Bradley. Compact I/O. 18 pins Spring type terminal block kit. £47.53. Price Per 1. Add to basket. Routeco Stock: 64 - Available now. Pricing/Availability request. ^ denotes Non-Returnable Product.Product Drawings. Offering a powerful range of product drawing tools to help you design & apply our products. Available on-line or for download, our tools help you access information while in the office or on the go. Technical Documentation Center. FAQs. Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8 User Manual. Important User Information 5069-RTB18-SCREW, 5069-RTB14CJC-SCREW: 0.4 Nm (3.5 lbin) Overvoltage protection, max ... Summary of Contents for Allen-Bradley 5069-IF8. Page 1 User Manual 5000 Series Analog I/O Modules in Logix5000 Control Systems Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8... Page 2 Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE). Allen-Bradley, Compact I/O, ControlLogix, Integrated ...Allen-Bradley. Dimensions: 4.29 in L x 1.01 in W. Item Status: Active. Manufacturer: Rockwell Automation. Name: Allen-Bradley 5069-IF8 Analog CompactLogix Input Module, 8 Inputs, 16 bit.Our Bulletin 5069 Compact 5000™ I/O modules provide high-performance control in a compact design, and expand the performance capabilities of the Logix platform. They are the local I/O modules in a CompactLogix™ 5380, Compact GuardLogix® 5380, or CompactLogix 5480 system and safety options are available. Summary of Contents for Allen-Bradley 5069-IF8. Page 1 User Manual 5000 Series Analog I/O Modules in Logix5000 Control Systems Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8... Page 2 Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE). Allen-Bradley, Compact I/O, ControlLogix, Integrated ... 5094-IF8, 5094-IF8XT Installation Download. 5094-IF8IH, 5094-IF8IHXT Installation ... FLEX 5000 Analog Isolated Current/Voltage/HART Input and Output Modules User Manual5094-IF8, 5094-IF8XT Installation Download. 5094-IF8IH, 5094-IF8IHXT Installation ... FLEX 5000 Analog Isolated Current/Voltage/HART Input and Output Modules User Manual1 Publication 1769-UM002B-EN-P - July 2005 Summary of Changes The 1769-IF8, -OF8C, and -OF8V modules have been added to this manual since the last printing. The 5069-IF8 analog 8-channel current/voltage input module offers non-isolated input channels that can connect to current or voltage input devices. The module supports multiple ranges for each input type. Compact 5000TM I/O modules use the Producer/Consumer communication model. 5069 Compact I/O 16 Channel 24VDC Sink Input Module. Lifecycle status: ACTIVE. Find a Distributor. Learn how to avoid the risks of unauthorized and counterfeit products. Find Product Drawings. Add to BoM. Get Support. 5069-IB16. Find a Distributor. View and Download Allen-Bradley 5069-IF8 user manual online. Analog I/O Modules 5000 Series in Logix5000 Control Systems. 5069-IF8 i/o systems pdf manual download. Important User Information Read this document and the documents listed in the additional resources section about...Manuals and User Guides for Allen-Bradley 5069-IF8. We have 1 Allen-Bradley 5069-IF8 manual available for free PDF download: User Manual Allen-Bradley 5069-IF8 User Manual (166 pages) Analog I/O Modules 5000 Series in Logix5000 Control Systems Brand: Allen-Bradley | Category: I/O Systems | Size: 5.55 MB Table of Contents Table of Contents 3I have the same issue on 2 installs. 5069-IQ16 24vdc input at reference does not initiate the input. Re-routing of the wiring solved the issue. 5069-IF8 input properly shielded had to be re-routed not to induce a fault on the card. I have discontinued using the 5069 i/o until AB solves the issue. RickControlLogix 8 Point A/I Module. Lifecycle status: ACTIVE. Find a Distributor. Find Product Drawings. Find Firmware & Downloads. Add to BoM. Get Support. 1756-IF8. Find a Distributor.I have the same issue on 2 installs. 5069-IQ16 24vdc input at reference does not initiate the input. Re-routing of the wiring solved the issue. 5069-IF8 input properly shielded had to be re-routed not to induce a fault on the card. I have discontinued using the 5069 i/o until AB solves the issue. RickI have the same issue on 2 installs. 5069-IQ16 24vdc input at reference does not initiate the input. Re-routing of the wiring solved the issue. 5069-IF8 input properly shielded had to be re-routed not to induce a fault on the card. I have discontinued using the 5069 i/o until AB solves the issue. Rick(1) Catalog numbers 5069-IF8 and 5069-IY4 support differential inputs only. Conversion Module Catalog Number Conversion Module Description 1746-NI8 5069-IF8 1492-CM1746-MO5 High Resolution (8) Analog Input Module 1746-NI4 5069-IY4 1492-CM1746-MO6 High Resolution (4) Analog Input Module5069-L310ERS2K, 5069-L310ERMS2K, 5069-L320ERS2K, 5069-L320ERMS2K, 5069-L330ERS2K, 5069-L330ERMS2K, 5069-L350ERS2K, 5069-L350ERMS2K Compact GuardLogix 5380 SIL 3 Controller Catalog Numbers 5069-L306ERMS3, 5069-L310ERMS3, 5069-L320ERMS3, 5069-L330ERMS3, 5069-L340ERMS3, 5069-L350ERMS3, 5069-L380ERMS3, 5069-L3100ERMS3 Compact GuardLogix 5380 SIL 35069-RTB18-SCREW RTB only: 0.4 Nm (3.5 lbin) Overvoltage protection, max. ±32V DC. Short circuit detection. Voltage mode only – output electronically limited to 16 mA or less. Data format. IEEE 32-bit floating point. Wire category. 2 - shielded input ports, 2 - power ports, 1 wire per terminal for each signal port.This manual describes how to install, configure, and troubleshoot your ControlLogix® digital I/O modules. There is also a complete listing of digital input and output modules, including specifications and wiring diagrams. You must be able to program and operate a ControlLogix controller to use your digital I/O module efficiently.Manuals and User Guides for Allen-Bradley 5069-IF8. We have 1 Allen-Bradley 5069-IF8 manual available for free PDF download: User Manual Allen-Bradley 5069-IF8 User Manual (166 pages) Analog I/O Modules 5000 Series in Logix5000 Control Systems Brand: Allen-Bradley | Category: I/O Systems | Size: 5.55 MB Table of Contents Table of Contents 3We have 1 Allen-Bradley 5069-IF8 manual available for free PDF download: User Manual Allen-Bradley 5069-IF8 User Manual (166 pages) Analog I/O Modules 5000 Series in Logix5000 Control SystemsThis manual shows how to monitor and handle major and minor controller faults. The manual also provides lists of major, minor, and I/O fault codes to use to troubleshoot the system. This manual is one of a set of related manuals that show common procedures for programming and operating Logix 5000 controllers.2 Rockwell Automation Publication 5069-TD001D-EN-P - October 2016 5069 Compact I/O Modules Specifications Summary of Changes Changes to the publication are listed in this table. Digital I/O Modules Topic Page Addition of information for the 5069-IA16 digital input module 3 Addition of information for the 5069-OA16 digital output module 18 4 Rockwell Automation Publication 5069-TD001G-EN-P - June 2018 Compact 5000 I/O Modules and EtherNet/IP Adapters 5069-IA16 Digital 16-point 120/240V AC Input Module This figure shows a wiring diagram for the 5069-IA16 module. 5069-IA16 Wiring Diagram Input Channel 0 Input Channel 1 Input Channel 2 Input Channel 3 Input Channel 4 Input Channel 5 ... 2 Rockwell Automation Publication 5069-IN015C-EN-P - December 2021 Compact 5000 Digital 16-point 120/240V AC Input Module Installation Instructions ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration and operation of this equipment before you install, configure, operate or ...Default If you're trying to use a common 3-wire analog device like a transmitter with +24V, analog out, and common, then I can 100% verify that they are compatabile with the IF8. Just requires a 24V power supply and tying the DC com to the (-) of the IF8 input channel. Yes, it’s a standard 3 wire analog. Can you confirm that on the 5069-if8 (not the ...5069-IF8 Installation Download. 5069-IY4, 5069-IY4K Installation ... Compact 5000 I/O High-Speed Counter Module User Manual Looking for more? Download. CompactLogix ...User ManualOriginal Instructions Compact 5000 I/O Analog Modules Catalog Numbers 5069-IF8, 5069-IY4, 5069-IY4K, 5069-OF4, 5069-OF4K, 5069-OF8 2Rockwell Automation Publication 5069-UM005C-EN-P - January 2022 Compact 5000 I/O Analog Modules User Manual Important User Information Australian RCM. IECEx Scheme. ATEX. This product was certified with the above certifications as of 2023-09-04. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.Allen-Bradley. Dimensions: 4.29 in L x 1.01 in W. Item Status: Active. Manufacturer: Rockwell Automation. Name: Allen-Bradley 5069-IF8 Analog CompactLogix Input Module, 8 Inputs, 16 bit.This manual shows how to monitor and handle major and minor controller faults. The manual also provides lists of major, minor, and I/O fault codes to use to troubleshoot the system. This manual is one of a set of related manuals that show common procedures for programming and operating Logix 5000 controllers. View and Download Allen-Bradley 5069-IF8 user manual online. Analog I/O Modules 5000 Series in Logix5000 Control Systems. 5069-IF8 i/o systems pdf manual download. Table 33 - 5069-IY4 Module - Configuration Tags Name Size Definition Chxx.HighSignal REAL One of four points used in...

Australian RCM. IECEx Scheme. ATEX. This product was certified with the above certifications as of 2023-09-04. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.. Pill 44 527

5069 if8 manual

The 5069-OB16, 5069-OB16F, and 5069-OB16K digital 16-point sourcing output modules drive output devices. The data that is sent to the modules from a controller and some input modules determines the 5069-OB16, 5069-OB16F, and 5069-OB16K module behavior. You can use time-scheduled output control on the 5069-OB16F output modules.The 5069-IF8 analog 8-channel current/voltage input module offers non-isolated input channels that can connect to current or voltage input devices. The module supports multiple ranges for each input type. Compact 5000TM I/O modules use the Producer/Consumer communication model. The 5069-OB16, 5069-OB16F, and 5069-OB16K digital 16-point sourcing output modules drive output devices. The data that is sent to the modules from a controller and some input modules determines the 5069-OB16, 5069-OB16F, and 5069-OB16K module behavior. You can use time-scheduled output control on the 5069-OB16F output modules. Analog I/O Module Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8 High-speed Counter Module Catalog Number 5069-HSC2xOB4 Serial Module Catalog Number 5069-SERIAL Field Potential Distributor Catalog Number 5069-FPD Address Reserve Module Catalog Number 5069-ARM EtherNet/IP Adapter Catalog Number 5069-AENTR, 5069-AEN2TRThis manual also provides system information you need to make system design choices. Logix5000 Controllers Common Procedures Manual, publication 1756-PM001 Guides the development of projects for Logix5000™ controllers. It provides links to individual guides. Logix5000 Controllers General Instruction Set Reference Manual, publication 1756-RM003User Manual. Original Instructions. 5000 Series Analog I/O Modules in Logix5000 Control Systems. Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8.Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8 User Manual. Important User InformationAnalog I/O Module Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8 High-speed Counter Module Catalog Number 5069-HSC2xOB4 Serial Module Catalog Number 5069-SERIAL Field Potential Distributor Catalog Number 5069-FPD Address Reserve Module Catalog Number 5069-ARM EtherNet/IP Adapter Catalog Number 5069-AENTR, 5069-AEN2TRI saw this thread and thought "there's no way in the world a 5069-IF8 doesn't support 3 wire transmitters" and figured I'd find a working example onsite to prove it, then post back. I then promptly forgot about it. But I remembered this morning, and yes, I have wired 2, 3 and 4 wire 4-20mA transmitters to a 5069-IF8 and it works just fine. Our Bulletin 5069 Compact 5000™ I/O modules provide high-performance control in a compact design, and expand the performance capabilities of the Logix platform. They are the local I/O modules in a CompactLogix™ 5380, Compact GuardLogix® 5380, or CompactLogix 5480 system and safety options are available. Australian RCM. IECEx Scheme. ATEX. This product was certified with the above certifications as of 2023-09-04. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8 User Manual. Important User InformationSummary of Changes This manual contains new and updated information as indicated in the following table. Topic Page Added 5094-IRT8S and 5094-IRT8SXT module information. Throughout. Added topic on Manual Conventions. 10 Added topic on Feature Support. 10 Added Terminology. 10 Added topic on Controller and Software Compatibility. 16 The 5069-IY4 has an input resolution of 15-bits plus sign and 16 bits for voltage; 16-bits for current, RTD and Thermocouple. Is the Thermocouple input provided with CJC sensors? Yes. Two (2) CJC sensors are available. What is the scan time of the 5069-IY4? The 5069-IY4 has rated scan time of 625 µs per channel and 2.5 ms per group.Default This manual also provides system information you need to make system design choices. Logix5000 Controllers Common Procedures Manual, publication 1756-PM001 Guides the development of projects for Logix5000™ controllers. It provides links to individual guides. Logix5000 Controllers General Instruction Set Reference Manual, publication 1756-RM003Analog I/O Module Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8 High-speed Counter Module Catalog Number 5069-HSC2xOB4 Serial Module Catalog Number 5069-SERIAL Field Potential Distributor Catalog Number 5069-FPD Address Reserve Module Catalog Number 5069-ARM EtherNet/IP Adapter Catalog Number 5069-AENTR, 5069-AEN2TR5069-L310ERS2K, 5069-L310ERMS2K, 5069-L320ERS2K, 5069-L320ERMS2K, 5069-L330ERS2K, 5069-L330ERMS2K, 5069-L350ERS2K, 5069-L350ERMS2K Compact GuardLogix 5380 SIL 3 Controller Catalog Numbers 5069-L306ERMS3, 5069-L310ERMS3, 5069-L320ERMS3, 5069-L330ERMS3, 5069-L340ERMS3, 5069-L350ERMS3, 5069-L380ERMS3, 5069-L3100ERMS3 Compact GuardLogix 5380 SIL 3110Rockwell Automation Publication 5069-TD001M-EN-P - April 2022 Compact 5000 I/O Modules and EtherNet/IP Adapters. 5069-SERIAL Serial Module. The Compact 5000 I/O serial module provides a network interface to RS-232, RS-422, and RS-485 devices. The following figure sho ws the 5069-SERIAL serial module..